GN-01

Working

Generator set · Cummins C300D6 (2016) · 2,930 h · Scroggie Creek

Last seen 11:19:10

Digital twin
Live machine view
Work cycle, load, fuel and lamps follow live telemetry. Drag to rotate, scroll to zoom.
Working
Assignment
Power WP-1
Unattended unit

Wash plant

s-scr-wp1

Hours today

3.5 h

Cycle time

—

Cycles today

—

Engine hours

2,930 h

Next service

in 253 h

Telemetry
Live readings

Engine speed

1,803rpm

Coolant

91.3°C

Output

242kW

Voltage

605V

Frequency

60.12Hz

Fuel burn

29.4L/h
Fuel
Tank level
67%

454 L

In tank

29.4 L/h

Burn

15.5 h

Range

Utilisation
Hours on this shift

3.5 h

of a 12 h shift · 29% utilisation

Load

76%

Engine speed

1,715 rpm

Coolant

91 °C

Per hour
Utilisation and fuel burned today
Production day starts at 07:00.

Utilisation · %

Fuel · L

Alarms
Alarms (1)

Frequency out of band

2026-11-17 15:28

Low
Engine history
Engine speed, coolant and fuel level

Engine speed · rpm

Coolant · °C

Fuel level · %