Serra de l'Ebre

Needs attention

Catalonia · Wind · 57 MW installed · 5 technicians · manager Firas Cheaib

Output now

10.8 MW

Load factor

19 %

Energy today

175 MWh

Availability

96.6 %

Producing

9 / 13

Open alarms

6

Generation
Last 12 hours
Wind, solar and battery power at the point of interconnection. A charging battery shows below zero.
Conditions
Resource and grid

Wind

9.2 m/s W

Irradiance

340 W/m²

Temperature

21.4 °C

Cloud cover

39 %

Conditions

Sunny intervals

Substation

Ascó SE 400 kV

Voltage

401.4 kV

Frequency

50.014 Hz

Power factor

0.996

Curtailment

8 %

Day-ahead price

70.01 €/MWh

Assets

13 assets on site. Open one for its live 3D view.

Power flow

Wind turbine

WTG-01

Nordex N163/5.X · 5.0 MW

Maintenance
0%

Output

0.00 MW

Today

6.7 MWh

Wind

7.8 m/s

Wind turbine

WTG-02

Nordex N163/5.X · 5.0 MW

Producing
12%

Output

0.62 MW

Today

17.2 MWh

Wind

7.1 m/s

Wind turbine

WTG-03

Siemens Gamesa SG 5.0-145 · 6.2 MW

Producing
47%

Output

2.90 MW

Today

32.6 MWh

Wind

9.7 m/s

Wind turbine

WTG-04

Siemens Gamesa SG 5.0-145 · 5.0 MW

Producing
18%

Output

0.90 MW

Today

19.0 MWh

Wind

7.7 m/s

Wind turbine

WTG-05

Siemens Gamesa SG 6.6-170 · 6.2 MW

Maintenance
0%

Output

0.00 MW

Today

8.3 MWh

Wind

9.3 m/s

Wind turbine

WTG-06

Vestas V162-6.2 · 5.0 MW

Producing
51%

Output

2.53 MW

Today

16.4 MWh

Wind

10.1 m/s

Wind turbine

WTG-07

Siemens Gamesa SG 5.0-145 · 5.0 MW

Standby
0%

Output

0.00 MW

Today

21.8 MWh

Wind

10.4 m/s

Wind turbine

WTG-08

Nordex N149/4.0-4.5 · 5.0 MW

Producing
4%

Output

0.21 MW

Today

16.8 MWh

Wind

5.7 m/s

Wind turbine

WTG-09

Siemens Gamesa SG 6.6-170 · 6.2 MW

Curtailed
9%

Output

0.55 MW

Today

12.3 MWh

Wind

7.9 m/s

Wind turbine

WTG-10

Siemens Gamesa SG 6.6-170 · 4.2 MW

Producing
43%

Output

1.79 MW

Today

13.4 MWh

Wind

9.7 m/s

Wind turbine

WTG-11

Vestas V162-6.2 · 4.2 MW

Producing
30%

Output

1.25 MW

Today

10.2 MWh

Wind

8.7 m/s

Inverter skid

INV-01

Sungrow SG3125HV-MV · 4.6 MVA

Producing
12%

Output

0.55 MW

Today

21.6 MWh

Availability

99.5 %

Inverter skid

INV-02

SMA Sunny Central 4600 UP · 3.1 MVA

Producing
6%

Output

0.17 MW

Today

13.1 MWh

Availability

96.3 %

Alarms
Site alarms
Most recent events from this site's assets.

Blade ice detected

WTG-09· 11-18 08:12
Medium

Generator winding temperature high

WTG-01· 11-18 02:01
Medium

Yaw misalignment above limit

WTG-05· 11-18 00:53
Low

Pitch system hydraulic pressure low

WTG-02· 11-17 20:35
Medium

Cooling fan failure

INV-01· 11-17 17:55
Low

Service interval exceeded

WTG-06· 11-17 16:40
Medium