Altiplano Híbrido

Needs attention

Murcia · Wind + solar + storage · 74 MW installed · 8 technicians · manager John Ingram

Output now

6.8 MW

Load factor

9 %

Energy today

74 MWh

Availability

97.1 %

Producing

21 / 29

Open alarms

10

Generation
Last 12 hours
Wind, solar and battery power at the point of interconnection. A charging battery shows below zero.
Conditions
Resource and grid

Wind

6.6 m/s SE

Irradiance

423 W/m²

Temperature

23.3 °C

Cloud cover

23 %

Conditions

Sunny intervals

Substation

Yecla SE 220 kV

Voltage

219.2 kV

Frequency

50.034 Hz

Power factor

0.987

Curtailment

7 %

Day-ahead price

86.81 €/MWh

Assets

29 assets on site. Open one for its live 3D view.

Power flow

Wind turbine

WTG-01

Siemens Gamesa SG 6.6-170 · 5.0 MW

Maintenance
0%

Output

0.00 MW

Today

6.7 MWh

Wind

6.9 m/s

Wind turbine

WTG-02

Nordex N163/5.X · 4.2 MW

Producing
11%

Output

0.44 MW

Today

8.6 MWh

Wind

6.8 m/s

Wind turbine

WTG-03

Siemens Gamesa SG 6.6-170 · 4.2 MW

Producing
39%

Output

1.63 MW

Today

7.0 MWh

Wind

9.4 m/s

Wind turbine

WTG-04

Vestas V150-4.2 · 6.2 MW

Maintenance
0%

Output

0.00 MW

Today

8.3 MWh

Wind

2.8 m/s

Wind turbine

WTG-05

Vestas V150-4.2 · 5.0 MW

Maintenance
0%

Output

0.00 MW

Today

6.7 MWh

Wind

3.1 m/s

Wind turbine

WTG-06

Vestas V162-6.2 · 5.0 MW

Producing
6%

Output

0.29 MW

Today

6.0 MWh

Wind

6.0 m/s

Tracker block

PV-01

Nextracker NX Horizon · 2.4 MWp

Producing
33%

Output

0.79 MW

Today

1.5 MWh

Availability

96.3 %

Tracker block

PV-02

Soltec SF7 · 2.4 MWp

Producing
23%

Output

0.56 MW

Today

1.7 MWh

Availability

99.2 %

Tracker block

PV-03

Array Technologies DuraTrack HZ v3 · 2.4 MWp

Producing
30%

Output

0.73 MW

Today

1.4 MWh

Availability

93.3 %

Tracker block

PV-04

Array Technologies DuraTrack HZ v3 · 4.0 MWp

Producing
20%

Output

0.78 MW

Today

2.8 MWh

Availability

97.5 %

Tracker block

PV-05

Soltec SF7 · 2.4 MWp

Producing
27%

Output

0.65 MW

Today

1.2 MWh

Availability

93.0 %

Tracker block

PV-06

Soltec SF7 · 4.0 MWp

Producing
36%

Output

1.44 MW

Today

2.2 MWh

Availability

95.5 %

Tracker block

PV-07

Soltec SF7 · 2.4 MWp

Producing
37%

Output

0.89 MW

Today

1.5 MWh

Availability

99.5 %

Tracker block

PV-08

Array Technologies DuraTrack HZ v3 · 2.4 MWp

Maintenance
0%

Output

0.00 MW

Today

3.2 MWh

Availability

95.8 %

Tracker block

PV-09

Nextracker NX Horizon · 3.2 MWp

Producing
26%

Output

0.82 MW

Today

2.0 MWh

Availability

99.7 %

Tracker block

PV-10

Soltec SF7 · 4.0 MWp

Producing
20%

Output

0.80 MW

Today

2.2 MWh

Availability

94.5 %

Tracker block

PV-11

Array Technologies DuraTrack HZ v3 · 4.0 MWp

Producing
37%

Output

1.48 MW

Today

2.2 MWh

Availability

98.7 %

Tracker block

PV-12

Soltec SF7 · 3.2 MWp

Curtailed
18%

Output

0.57 MW

Today

1.1 MWh

Availability

98.7 %

Tracker block

PV-13

Soltec SF7 · 4.0 MWp

Fault
0%

Output

0.00 MW

Today

5.4 MWh

Availability

96.8 %

Tracker block

PV-14

Array Technologies DuraTrack HZ v3 · 4.0 MWp

Producing
26%

Output

1.05 MW

Today

2.6 MWh

Availability

97.3 %

Inverter skid

INV-01

Sungrow SG3125HV-MV · 4.6 MVA

Maintenance
0%

Output

0.00 MW

Today

6.2 MWh

Availability

96.9 %

Inverter skid

INV-02

Sungrow SG3125HV-MV · 3.1 MVA

Producing
27%

Output

0.83 MW

Today

3.7 MWh

Availability

96.6 %

Inverter skid

INV-03

Huawei SUN2000-215KTL · 5.0 MVA

Producing
24%

Output

1.20 MW

Today

7.7 MWh

Availability

99.4 %

Inverter skid

INV-04

Huawei SUN2000-215KTL · 3.1 MVA

Curtailed
13%

Output

0.41 MW

Today

1.9 MWh

Availability

95.4 %

Inverter skid

INV-05

SMA Sunny Central 4600 UP · 4.6 MVA

Producing
21%

Output

0.95 MW

Today

5.4 MWh

Availability

98.5 %

Inverter skid

INV-06

Huawei SUN2000-215KTL · 4.6 MVA

Producing
18%

Output

0.84 MW

Today

5.2 MWh

Availability

99.5 %

Inverter skid

INV-07

SMA Sunny Central 4600 UP · 4.6 MVA

Producing
45%

Output

2.07 MW

Today

6.1 MWh

Availability

98.7 %

Battery container

BESS-01

CATL EnerOne+ · 5.0 MW

Producing
68%

Output

3.40 MW

Today

0.0 MWh

State of charge

47 %

Battery container

BESS-02

CATL EnerOne+ · 3.9 MW

Producing
70%

Output

2.73 MW

Today

0.0 MWh

State of charge

47 %

Alarms
Site alarms
Most recent events from this site's assets.

Pitch system hydraulic pressure low

WTG-01· 11-18 10:46
Medium

Row stowed – high wind

PV-03· 11-18 10:44
Medium

Rack isolated by BMS

BESS-01· 11-18 07:50
Low

Generator winding temperature high

WTG-05· 11-18 04:22
Low

Soiling loss above threshold

PV-13· 11-17 23:07
High

Soiling loss above threshold

PV-08· 11-17 19:47
Low

Anemometer signal lost

WTG-04· 11-17 18:26
Low

Soiling loss above threshold

PV-13· 11-17 18:03
High