DMU-03

DMG MORI DMU 50 (3rd Generation) · Siemens SINUMERIK ONE · Bay 1 · Cell C · s/n DMU50-22211

Live machine view
Five-axis cycle
X/Y/Z, the swivelling B trunnion and the C rotary table follow live telemetry; the door opens when the machine stops. Drag to rotate, scroll to zoom.
Cutting
Effectiveness
OEE this shift
Early (06:00–14:00) · 258 of 309 min running
61%

Availability

83.6%

Performance

74.7%

Quality

98.0%

Current job
WO-24117
Valve block · BH-9021-D

Pieces

7 / 20

Cycle time

6m 35s

This piece

45s elapsed

Operator

Sandro Pereira

Tool

T17 · Ø6 chamfer mill

Tool life left

16%

Finishes

18 Nov 12:14

Losses
Downtime by reason
50.7 minutes lost this shift, biggest first.

Setup / first-off

19.4 min

Tool change

10.6 min

No material

6.5 min

Waiting QA

5.8 min

Breakdown

5.6 min

No operator

2.9 min

Quality
Pieces this shift
Ideal 228 s versus actual 305 s per piece.

Good

49

Scrap

1

Rework

0

OEE per hour · %

Queue
Jobs on this machine (3)
The job on the spindle and everything queued behind it, earliest due date first.

WO-24117

Brunner Hydraulik · BH-9021-D OP30 · Al 6082 · setup 46 min

Late

7/20 · due 17 Nov 22:08

WO-24121

Sandvik Tooling · ST-3390-A OP20 · H13 tool steel · setup 35 min

Queued

0/20 · due 19 Nov 22:08

WO-24125

Hot

Helvetica Medtech · HM-2208-C OP10 · 316L stainless · setup 86 min

Queued

0/12 · due 20 Nov 22:08

Readings
Live telemetry
Polled every 5 seconds · spindle 14,433 h, service in 165 h

Spindle load

59 %

Spindle speed

8,884 rpm

Feed rate

1,620 mm/min

Spindle temp

47.2 °C

Coolant temp

26.3 °C

Coolant pressure

18.9 bar

Vibration

1.78 mm/s

Axis load B

30 %

Axis positions

X

-179.4

Y

-26.6

Z

-85.7

B

-52.8

C

155.2

Spindle history
Spindle load, speed and vibration

Spindle load · %

Spindle speed · rpm

Vibration · mm/s

Alarms
Alarms (8)

Door interlock opened during cycle

Alarm 6621 · 11-18 09:58

High

B axis drive temperature high

Alarm 1105 · 11-18 09:08

Medium

Tool life expired on T7, change required

Alarm 2019 · 11-18 08:46

Low

Tool life expired on T7, change required

Alarm 2019 · 11-17 09:12

High

C axis following error

Alarm 1188 · 11-17 00:17

Medium

Coolant level low in the tank

Alarm 7014 · 11-16 19:37

High

Coolant level low in the tank

Alarm 7014 · 11-16 18:50

High

Coolant level low in the tank

Alarm 7014 · 11-16 14:54

High