Alcázar Solar

Needs attention

Castilla-La Mancha · Solar PV · 35 MW installed · 4 technicians · manager Thomas Winter

Output now

8.1 MW

Load factor

23 %

Energy today

22 MWh

Availability

95.7 %

Producing

14 / 18

Open alarms

6

Generation
Last 12 hours
Wind, solar and battery power at the point of interconnection. A charging battery shows below zero.
Conditions
Resource and grid

Wind

2.2 m/s E

Irradiance

357 W/m²

Temperature

22.1 °C

Cloud cover

41 %

Conditions

Partly cloudy

Substation

Alcázar SE 220 kV

Voltage

220.3 kV

Frequency

50.007 Hz

Power factor

0.986

Curtailment

6 %

Day-ahead price

69.59 €/MWh

Assets

18 assets on site. Open one for its live 3D view.

Power flow

Tracker block

PV-01

Soltec SF7 · 2.4 MWp

Producing
46%

Output

1.11 MW

Today

1.9 MWh

Availability

94.8 %

Tracker block

PV-02

Nextracker NX Horizon · 4.0 MWp

Producing
33%

Output

1.33 MW

Today

2.3 MWh

Availability

95.0 %

Tracker block

PV-03

Nextracker NX Horizon · 2.4 MWp

Producing
19%

Output

0.45 MW

Today

1.3 MWh

Availability

93.8 %

Tracker block

PV-04

Array Technologies DuraTrack HZ v3 · 2.4 MWp

Producing
27%

Output

0.65 MW

Today

1.5 MWh

Availability

98.3 %

Tracker block

PV-05

Soltec SF7 · 3.2 MWp

Producing
15%

Output

0.49 MW

Today

2.2 MWh

Availability

97.3 %

Tracker block

PV-06

Soltec SF7 · 4.0 MWp

Standby
0%

Output

0.00 MW

Today

2.4 MWh

Availability

94.4 %

Tracker block

PV-07

Array Technologies DuraTrack HZ v3 · 2.4 MWp

Standby
0%

Output

0.00 MW

Today

1.5 MWh

Availability

97.3 %

Tracker block

PV-08

Array Technologies DuraTrack HZ v3 · 2.4 MWp

Producing
29%

Output

0.71 MW

Today

1.8 MWh

Availability

93.7 %

Tracker block

PV-09

Array Technologies DuraTrack HZ v3 · 2.4 MWp

Curtailed
11%

Output

0.25 MW

Today

1.0 MWh

Availability

94.5 %

Tracker block

PV-10

Soltec SF7 · 4.0 MWp

Producing
29%

Output

1.16 MW

Today

2.6 MWh

Availability

93.9 %

Tracker block

PV-11

Nextracker NX Horizon · 3.2 MWp

Producing
40%

Output

1.27 MW

Today

2.3 MWh

Availability

97.4 %

Tracker block

PV-12

Array Technologies DuraTrack HZ v3 · 2.4 MWp

Producing
26%

Output

0.63 MW

Today

1.4 MWh

Availability

94.0 %

Inverter skid

INV-01

Huawei SUN2000-215KTL · 3.1 MVA

Producing
26%

Output

0.80 MW

Today

2.1 MWh

Availability

95.1 %

Inverter skid

INV-02

Huawei SUN2000-215KTL · 5.0 MVA

Producing
24%

Output

1.21 MW

Today

3.4 MWh

Availability

99.1 %

Inverter skid

INV-03

Sungrow SG3125HV-MV · 4.6 MVA

Producing
35%

Output

1.59 MW

Today

2.9 MWh

Availability

98.0 %

Inverter skid

INV-04

Sungrow SG3125HV-MV · 5.0 MVA

Producing
18%

Output

0.92 MW

Today

3.2 MWh

Availability

94.9 %

Inverter skid

INV-05

Sungrow SG3125HV-MV · 5.0 MVA

Fault
0%

Output

0.00 MW

Today

6.8 MWh

Availability

94.8 %

Inverter skid

INV-06

Huawei SUN2000-215KTL · 4.6 MVA

Producing
38%

Output

1.73 MW

Today

3.7 MWh

Availability

96.1 %

Alarms
Site alarms
Most recent events from this site's assets.

Transformer oil level low

INV-05· 11-18 10:25
Medium

DC insulation resistance low

INV-05· 11-18 07:28
Medium

Row stowed – high wind

PV-10· 11-18 01:21
Low

Grid voltage out of band

INV-05· 11-18 01:10
Medium

Grid voltage out of band

INV-01· 11-17 20:22
Medium

Tracker stuck – motor current high

PV-01· 11-17 13:36
Low